Measuring Board VACUUM V6
for Reflow Vapour Phase/Vacuum
The Reflow Vapour Phase/Vacuum measuring board has eight thermocouples of the highest accuracy class. These are placed on specially designed measuring fields with excellent long-term stability and are optimized for the vapour phase and vacuum process. The VP measuring board is designed to control and optimize the system parameters during these two processes.
| Technical highlights |
|---|
| Measuring range 0 to +795 °C |
| 2,4 GHz real-time-data – WIFI onboard |
| 8 channels + internal temperature |
| Display battery capacity 0-100% |
| 0.1 s measuring interval (10 Hz) |
| Internal storage for 5 x 35 min measuring time |
| Live temperature display |
| High-precision 16-bit ADC onboard |
| Automatic offset compensation & cold junction compensation |
| Operation and charging via USB-C |
| WIFI access point or infrastructure operation |
| No driver installation necessary (WIFI connection) |
| NiMH battery, no memory effect, replaceable |
| Protection against over-/deep discharge |
| DIN ISO 584 High-temp mini connector |
| Order Numbers |
|---|
| 0GP-VA-2540 (250 mm x 400 mm) 1x measuring board VACUUM V6 with 8 thermocouples Ni/CrNi 0GP-VA-5040 (500 mm x 400 mm) 1x measuring board VACUUM V6 with 8 thermocouples Ni/CrNi |
Measuring Board VACUUM V6
for Reflow Vapour Phase/Vacuum
The Reflow Vapour Phase/Vacuum measuring board has eight thermocouples of the highest accuracy class. These are placed on specially designed measuring fields with excellent long-term stability and are optimized for the vapour phase and vacuum process. The VP measuring board is designed to control and optimize the system parameters during these two processes.
- Technical highlights
- Measuring range 0 to +795 °C
- 2,4 GHz real-time-data – WIFI onboard
- 8 channels + internal temperature
- Display battery capacity 0-100%
- 0.1 s measuring interval (10 Hz)
- Internal storage for 5 x 35 min measuring time
- Live temperature display
- High-precision 16-bit ADC onboard
- Automatic offset compensation & cold junction compensation
- Operation and charging via USB-C
- WIFI access point or infrastructure operation
- No driver installation necessary (WIFI connection)
- NiMH battery, no memory effect, replaceable
- Protection against over-/deep discharge
- DIN ISO 584 High-temp mini connector
- Order Numbers
- 0GP-VA-2540 (250 mm x 400 mm) 1x measuring board VACUUM V6 with 8 thermocouples Ni/CrNi
0GP-VA-5040 (500 mm x 400 mm) 1x measuring board VACUUM V6 with 8 thermocouples Ni/CrNi