Measuring Board WAVE V6
for wave soldering
The measuring board WAVE V6 includes eight thermocouples of the highest accuracy class. These are located on specially designed measuring fields with excellent long-term stability and optimized for the wave soldering process. The measuring board WAVE V6 is designed to control the system parameters and to optimize them in the wave soldering system.
| Technical highlights |
|---|
| Measuring range 0 to +795 °C |
| 2,4 GHz real-time-data – WIFI onboard |
| 8 channels + internal temperature |
| Display battery capacity 0-100% |
| 0.1 s measuring interval (10 Hz) |
| Internal storage for 5 x 35 min measuring time |
| Live temperature display |
| High-precision 16-bit ADC onboard |
| Automatic offset compensation & cold junction compensation |
| Operation and charging via USB-C |
| WIFI access point or infrastructure operation |
| No driver installation necessary (WIFI connection) |
| NiMh battery, no memory effect, replaceable |
| Protection against over-/deep discharge |
| DIN ISO 584 High-temp mini connector |
| Downloads |
|---|
| Datasheet Measuring Board WAVE v6 |
| Order Numbers |
|---|
| 0GP-WE001: 1x measuring board WAVE V6 with 8 thermocouples Ni/CrNi and shuttle hood |
Measuring Board WAVE V6
for wave soldering
The measuring board WAVE V6 includes eight thermocouples of the highest accuracy class. These are located on specially designed measuring fields with excellent long-term stability and optimized for the wave soldering process. The measuring board WAVE V6 is designed to control the system parameters and to optimize them in the wave soldering system.
- Technical highlights
- Measuring range 0 to +795 °C
- 2,4 GHz real-time-data – WIFI onboard
- 8 channels + internal temperature
- Display battery capacity 0-100%
- 0.1 s measuring interval (10 Hz)
- Internal storage for 5 x 35 min measuring time
- Live temperature display
- High-precision 16-bit ADC onboard
- Automatic offset compensation & cold junction compensation
- Operation and charging via USB-C
- WIFI access point or infrastructure operation
- No driver installation necessary (WIFI connection)
- NiMh battery, no memory effect, replaceable
- Protection against over-/deep discharge
- DIN ISO 584 High-temp mini connector
- Downloads
- Datasheet Measuring Board WAVE v6
- Order Numbers
- 0GP-WE001:
1x measuring board WAVE V6 with 8 thermocouples Ni/CrNi and shuttle hood